IEC 60851-5:2008+A1:2011+A2:2019 specifies the following tests:
- Test 5: Electrical resistance,
- Test 13: Breakdown voltage,
- Test 14: Continuity of insulation,
- Test 19: Dielectric dissipation factor.
Significant revisions to the previous edition include the following points:
- In Subclause 5.3, the addition of the use of carbon brush electrodes for the counting discontinuities during the high voltage continuity test, as an alternative to the V-groove pulley electrode, and
- Clarifications in the breakdown voltage test for round wires larger than 2,500 mm and for fibrous covered wires.
THIS CONSOLIDATED VERSION CONSISTS OF THE FOURTH EDITION (2008), ITS AMENDMENT 1 (2011) AND ITS AMENDMENT 2 (2019). THEREFORE, NO NEED TO ORDER AMENDMENT IN ADDITION TO THIS PUBLICATION.