1.1 ,This test method describes the determination of the approximate total acid value of used electrical insulating liquids having viscosities less than 24 cSt at 40°,C. It is a simple procedure that can be applied in the field. Where a quantitative neutralization value is required, use Test Method D664 or Test Method D974. These test methods should be applied in the laboratory.